Mean Well RSP Series · 9 Rails · Universal 85–264 VAC · Active PFC · Fanless 30 mm

Mean Well RSP-150 Switching Power Supply

The Mean Well RSP-150 switching power supply pairs a 5 V / 30 A / 150 W rail (nine rails from 3.3 to 48 V in the series) with an 85–264 VAC universal input, built-in active PFC, remote ON/OFF control and a fanless 30 mm chassis — the first supply on this site that runs natively on 110–120 V grids.

📱 / WhatsApp: +86-191-18802497 · Shenzhen, China · GMT+8

Mean Well RSP-150 switching power supply angled hero view with honeycomb mesh cover and label

150 W

Rated output (5 V rail)

5 V / 30 A

DC output rail

85–264 VAC

Universal input + PFC

Fanless

Free air convection, 30 mm

3 Years

Warranty (2.25M h MTBF)

Short answer

The Mean Well RSP-150 is a 150 W fanless switching power supply with a universal 85–264 VAC input and built-in active PFC. The 5 V model delivers 30 A (150 W); the series spans nine rails from 3.3 V to 48 V, all in a 199 × 99 × 30 mm chassis with remote ON/OFF control, 4 kVAC isolation, a 3-year warranty and a 2,253,900-hour Telcordia MTBF rating. It is the PFC-equipped, grid-agnostic member of the Mean Well LED-screen power set — and the one unit here that American, Japanese and Taiwanese 110–120 V walls can feed directly.

What Is the Mean Well RSP-150 Switching Power Supply?

The Mean Well RSP-150 is a 150 W single-output enclosed AC/DC switching power supply (SMPS) that converts a universal 85–264 VAC mains feed into one tightly regulated DC rail. The series ships nine rails — 3.3, 5, 7.5, 12, 13.5, 15, 24, 27 and 48 V — with the 5 V model rated 30 A, and it cools by free air convection with no fan at all, in a perforated 199 × 99 × 30 mm chassis weighing 0.6 kg.

Two engineering choices separate the RSP-150 from the rest of the Mean Well screens set. First, the active PFC front end (power factor above 0.93 at 230 VAC and above 0.98 at 115 VAC) — the same feature that makes the CZCL A-400JQ-5P special in its family, here in a 150 W chassis. Second, the built-in remote ON/OFF control on a JST connector, letting a timer or room controller switch the DC bus without breaking mains. Mean Well backs the platform with a 3-year warranty and a dual-method MTBF: 2,253,900 hours minimum by Telcordia SR-332 plus 290,700 hours minimum by MIL-HDBK-217F at 25°C.

Runs anywhere on earth

85–264 VAC universal input covers 110–120 V and 220–240 V grids alike — no narrow-window restrictions, no step-up transformer for US or Japanese sites.

Silent, sealed, serviceable

Fanless convection at up to +70°C, LED power-on indicator, and a remote ON/OFF pin pair for centralized or scheduled switching.

Certified beyond the screen market

UL 62368-1, TUV, CCC, EAC, BSMI, AS/NZS and IS13252 approvals plus EN 61000-3-2 harmonic compliance — the factory automation pedigree shows.

Planning a screen’s full electrical side? Pair this page with the LED display power consumption guide, and for the control end of the same cabinet see the LED screen display control system catalog.

What Are the Mean Well RSP-150 Switching Power Supply Specifications?

Every figure below comes from the official Mean Well RSP-150 specification sheet (3 pages, revision dated 2025-09-22). The nine-rail table first, then the platform parameters shared by every model:

Model Rail / current Rated power Tolerance Ripple (max.) Efficiency
RSP-150-3.3 3.3 V / 30 A 99 W ±2.0% 100 mVp-p 81.5%
RSP-150-5 5 V / 30 A 150 W ±2.0% 100 mVp-p 87%
RSP-150-7.5 7.5 V / 20 A 150 W ±2.0% 100 mVp-p 88.5%
RSP-150-12 12 V / 12.5 A 150 W ±2.0% 100 mVp-p 89%
RSP-150-13.5 13.5 V / 11.2 A 151.2 W ±2.0% 100 mVp-p 87.5%
RSP-150-15 15 V / 10 A 150 W ±2.0% 100 mVp-p 88.5%
RSP-150-24 24 V / 6.3 A 151.2 W ±1.0% 150 mVp-p 89%
RSP-150-27 27 V / 5.6 A 151.2 W ±1.0% 150 mVp-p 89.5%
RSP-150-48 48 V / 3.2 A 153.6 W ±1.0% 250 mVp-p 90%
Common to all nine rails Value
Input voltage range 85–264 VAC / 120–370 VDC, 47–63 Hz (nameplate: 100–240 V, 1.9 A)
Power factor Active PFC: PF > 0.93 at 230 VAC; PF > 0.98 at 115 VAC, full load
Line / load regulation ±0.5% line; ±1.0% load (3.3/5/7.5 V), ±0.5% load (12–48 V)
Setup / hold-up time 600 ms, 30 ms / 16 ms at full load
Inrush / leakage current 45 A cold start at 230 VAC / <2 mA at 240 VAC
Protections Overload 105–135%: constant current limiting, auto-recovery; OVP: shut down, re-power on to recover; OTP: shut down, auto-recovery; short circuit
Remote control CN1 (JST XH, optional): 0–0.8 VDC power ON, 4–10 VDC power OFF
Cooling / working temp Free air convection (fanless) / −30°C to +70°C with derating curve
Withstand voltage I/P-O/P 4 kVAC, I/P-FG 2 kVAC, O/P-FG 0.5 kVAC; isolation 100 MΩ
MTBF 2,253.9K hrs min. (Telcordia SR-332); 290.7K hrs min. (MIL-HDBK-217F, 25°C)
Dimensions / packing 199 × 99 × 30 mm (Case 215A) / 0.6 kg, 24 pcs per carton
Safety / EMC UL 62368-1, TUV EN 62368-1, EN 61558-1/-2-16, EAC TP TC 004, CCC GB 4943.1, BSMI, AS/NZS 62368-1, IS 13252 (except 7.5/13.5/48 V); EN 55032 Class B, EN 61000-3-2/-3, EN 55035
Warranty 3 years

Mean Well RSP-150 mechanical drawing 199 x 99 x 30 mm Case 215A with terminal and remote connector positions

Factory mechanical drawing: 199 × 99 × 30 mm, Case 215A, 7-pin terminal plus CN1 remote

Universal input comes with one rule: read the low-voltage derating

The datasheet specifies 85–264 VAC, while the production nameplate reads 100–240 V, 1.9 A (the photo below shows both). The factory curve fills the gap: at 115 VAC and above the unit carries full rated load; on an 85–100 V grid the output derates to roughly 80% (datasheet Note 5 — “derating may be needed under low input voltages”). Also note OVP behavior: unlike the overload protection, an over-voltage trip latches until you re-power the unit.

Mean Well RSP-150-12 nameplate close-up 100-240VAC input with remote control terminal and output block

Production nameplate: INPUT 100–240 VAC, 1.9 A · R.C. remote pins and +V ADJ trimmer beside the 7-pin terminal

The published ripple figures follow the same factory measurement discipline as the rest of the range — here is Mean Well’s own method video, the same habit our bench applies before any batch ships:

How Many LED Modules Can the Mean Well RSP-150 5 V Rail Carry?

Apply the industry-standard 80% loading rule and the RSP-150-5 gives you two budgets:

Power budget

150 W × 80% = 120 W usable per unit

Current budget

30 A × 80% = 24 A usable per unit

Mapped onto typical modules (average draws under normal program material — full-white patterns run higher, so verify against your module datasheet):

Typical load Average draw Max per RSP-150-5 at 120 W
Indoor P2.5 module (320 × 160 mm) ~10–15 W ~8–12 modules
Rental P3.91 module (250 × 250 mm) ~15–20 W ~6–8 modules
Outdoor P4.81 module (250 × 250 mm) ~20–30 W ~4–6 modules
Receiving card (Novastar / Colorlight class) ~3–5 W Shares the same 5 V rail

One RSP-150-5 therefore covers a 500 × 500 mm indoor cabinet outright; bigger bays step up the Mean Well ladder — the 400 W Mean Well NEL-400 or the 500 W LRS-600 — with the full derating math in our power consumption walkthrough.

Why Does the Mean Well RSP-150 Include Active PFC?

Power factor correction is the quiet feature that separates the RSP-150 from every budget LED supply in this comparison set. The active PFC stage shapes the input current draw so the supply looks resistive to the grid: PF above 0.93 at 230 VAC and above 0.98 at 115 VAC at full load. Three practical consequences follow:

Harmonics compliance

The datasheet lists EN 61000-3-2 and EN 61000-3-3 harmonic compliance — the class of requirement that matters on commercial and light-industrial installs in Europe.

Long cable runs and generators

A corrected input tolerates lossy distribution and generator power far better — event sites, temporary feeds and long AC runs keep cleaner DC on the other side.

More real watts per breaker

At PF ≈ 1 the supply draws 0.8 A from a 230 V wall at full load — a screen full of RSP-150 units loads breakers and cables predictably, with no reactive penalty.

The trade is historical, not technical: PFC circuitry adds a front-end stage, which is why Mean Well’s own LRS line omits it for cost and the RSP line exists. If your project never leaves a 230 V residential circuit, the LRS remains the value pick; the moment harmonics, generators or 115 V grids enter the picture, the RSP earns its premium.

Which Input Grids Can the Mean Well RSP-150 Run On?

All of them — with one derating rule attached. The 85–264 VAC window spans every common residential and commercial grid on the planet, and the unit carries full rated load from 115 VAC upward. Below that, the factory curve derates the output gradually to roughly 80% at the 85 V floor:

Grid Verdict on the RSP-150
220–240 V (EU, UK, Middle East, Asia, AU) Full rated load; the design center the nameplate quotes (100–240 V)
110–120 V (US, Canada, Japan, Taiwan) Full rated load at 115 V+ — the only supply family on this site with no transformer caveat for these grids
85–100 V (brownout-prone 100 V grids) Runs, but derate the load to roughly 80% per the factory curve (Note 5)

Two more environment notes from the datasheet: the unit is rated for over-voltage category III up to 2,000 m altitude and category II up to 5,000 m (above 2,000 m, apply the 3.5°C per 1,000 m temperature derating), and the −30°C to +70°C working window makes it the widest-temperature fanless chassis in this comparison set — though the 3.3–7.5 V rails begin derating near 40°C while the 12–48 V rails hold full load to 50°C, so check the curve for your rail before promising full output in a hot cabinet.

Mean Well RSP-150 switching power supply side view showing slim 30 mm low profile chassis

Side profile: the 30 mm fanless chassis behind the universal input rating

Which of the Nine Mean Well RSP-150 Rails Fits Your Screen?

Every rail ships in the same chassis at the same 85–264 VAC input — only the DC bus changes:

LED screen bays: 5 V / 30 A

The RSP-150-5 feeds standard modules and receiving cards; a 120 W budget covers a 500 × 500 mm indoor cabinet with headroom.

Low-voltage rails: 3.3 / 7.5 V

The 99 W 3.3 V rail serves common-cathode energy-saving work (read our common cathode LED technology explainer); 7.5 V covers specialty strings. Both derate from about 40°C ambient.

Signage and control: 12–48 V

12, 13.5, 15, 24, 27 and 48 V rails cover strip signage, controllers and telecom-style buses at ±1.0% tolerance on the top three rails.

Two Mean Well RSP-150 units top view RSP-150-12 and RSP-150-7.5 with perforated mesh covers

Two rails of the series side by side — RSP-150-12 and RSP-150-7.5 nameplates, same chassis and mesh cover

Mean Well RSP-150-5 vs CZCL A-200AC-5: Which 5 V Supply Fits Your Cabinet?

The two 5 V workhorses on this site meet here from opposite philosophies — the CZCL unit wins on raw current, the Mean Well wins on grid freedom and paperwork:

  1. Input window: 85–264 VAC universal versus 190–264 VAC — only the RSP-150-5 can be plugged into a 110 V wall.
  2. Current class: the A-200AC-5 carries 40 A / 200 W against the RSP-150-5’s 30 A / 150 W — one CZCL unit feeds roughly a third more modules.
  3. Power factor: active PFC (PF > 0.98 at 115 V) with EN 61000-3-2 compliance versus no PFC stage.
  4. Control: the RSP-150-5 adds remote ON/OFF on CN1 — scheduled or centralized bus switching the CZCL unit cannot do.
  5. Documentation: dual-method MTBF (2.25M h Telcordia / 290.7K MIL-HDBK-217F) and a 3-year warranty versus a 2-year term.
Parameter Mean Well RSP-150-5 CZCL A-200AC-5
Output 5 V / 30 A / 150 W 5 V / 40 A / 200 W
Input window 85–264 VAC universal (full load ≥115 VAC) 190–264 VAC (220–240 V grids only)
PFC Active, PF > 0.98 at 115 VAC None
Cooling / height Fanless / 30 mm Fanless / 26 mm
Efficiency (5 V rail) 87% 88%
Remote control CN1 remote ON/OFF None
Warranty / MTBF 3 years / 2,253.9K h Telcordia 2 years / not published

Full detail on the CZCL unit lives on the CZCL A-200AC-5 LED switching power page; trial one of each in the same cabinet and the grid and current differences will pick for you.

How Does the Mean Well RSP-150 Fit the LRS and NEL Families?

Mean Well’s three screen-relevant lines now divide the work cleanly, and the RSP-150 slots in as the compliance-and-control specialist:

LRS — the value line

Multi-rail from 150 W to the 500 W LRS-600; the LRS-150 covers the 12–48 V rails in the same fanless 30 mm format. No PFC, lowest cost.

NEL — the screen-native line

LED-only rails (2.8 / 4.2 / 5 V) with conformal coating standard and 80 A on the 5 V rail; the 400 W NEL-400 is the cabinet-volume pick.

RSP — the compliance line

Nine rails, active PFC, remote ON/OFF, 4 kVAC isolation and a 3-year warranty — the unit you spec when the site has generators, 115 V power, tender paperwork or scheduled switching.

On our own bench, serviceability is designed into the cabinet from day one — our stage-screen build runs a detachable PSU box so a failed unit swaps in minutes:

How Do You Install and Wire the Mean Well RSP-150 Safely?

The 7-pin terminal plus the CN1 remote pair define the wiring workflow:

Mean Well RSP-150 150W switching power supply rear view with mounting flanges both sides

Pin Assignment
1 / 2 AC/L · AC/N
3 FG (frame ground)
4, 5 DC output −V
6, 7 DC output +V

1 · Mount on the side flanges

Four M4 screws per side (L = 4 mm per the factory drawing) plus the mid-case tab. Keep the perforated cover unobstructed — convection is the only cooling.

2 · Wire AC, DC and ground

AC into pins 1–2, module and receiving-card bus across pins 6–7 (+V) and 4–5 (−V), FG bonded to cabinet earth. Check polarity with a meter before the first power-up — reversed DC is the fastest way to destroy a receiving card.

3 · Optional: wire the remote control

The CN1 JST pair switches the output remotely: 0–0.8 VDC powers ON, 4–10 VDC powers OFF — wire it to a timer or room controller for scheduled dark hours without touching mains.

4 · Set the rail with +V ADJ

Trim to 5.0 V (adjustable 4.75–5.5 V) at the far end of the DC bus under load, then confirm each cabinet measures the same within a few tenths.

5 · Mind the output capacitance limit

On the 3.3/5/7.5/12 V models the datasheet caps external output capacitance at 5,000 µF — oversized buffer banks on the DC bus can trip the start-up circuit.

6 · Load-test and verify

Run a full-white pattern for ten minutes, feel for hot spots, confirm the LED indicator stays lit, and re-torque the terminals before closing the cabinet.

Two protection behaviors to brief your crew on

Overload recovers on its own — constant current limiting rides through the fault and resumes when it clears. Overvoltage does not: an OVP trip latches the output off until the unit is re-powered, so after an OVP event, cycle the AC feed and then look for the upstream cause. And as with every non-current-sharing supply, do not parallel outputs for more current — split the bus by cabinet or step up the rail.

When a unit does fail in the field, our LED display power supply diagnostics and replacement guide walks the test-and-swap workflow end to end.

What Problems Does a Failing Mean Well RSP-150 Power Supply Cause?

Power trouble wears disguises — check these three signatures before blaming a module or a control card:

Dim or uneven brightness, one cabinet

Aging output capacitors sag the rail under load; the cabinet’s corner looks tired while its neighbors shine. Full-white patterns make it obvious.

Uneven brightness troubleshooting →

Flicker on camera or under load spikes

An overloaded or failing rail dips for a frame at a time. Flicker that tracks bright content points at the supply first.

Fix LED screen flickering →

Cabinet reboots or dead sections

Constant-current limiting reads as a dimmed bus rather than a hard off; a latched OVP reads as a dead cabinet until re-power. Measure the rail during the dropout before replacing modules.

Power supply diagnostics →

How Much Does the Mean Well RSP-150-5 Cost?

Authorized-distributor pricing sits at $39.70 for a single unit and $37.80 each at five-plus (Mouser, observed September 2026), with independent distributors at $38.60 (Bravo Electro). Volume pricing for screen-production quantities steps down from there — Mean Well packs this series 24 pieces to a carton.

Sample · 1–10 pcs

For repairs, prototypes and trial cabinets — shipped from stock with the cULus + EAC nameplate you see above.

Project · 10–500 pcs

Whole-screen and fleet quantities with per-cabinet load math and rail matching to your module datasheets.

Volume · 500+ pcs

Production-line pricing with container freight planning and batch date-code consistency.

Send the module types, modules-per-cabinet and total cabinet count, and the quote comes back with the load math attached — from an LED screen manufacturer that stocks the full chain from power to control.

Mean Well RSP-150 Switching Power Supply: Frequently Asked Questions

Can the RSP-150-5 run on a 110 V outlet in the US?

Yes — it is the one supply in this comparison set built for it. The 85–264 VAC universal input carries full rated load from 115 VAC upward; only an 85–100 V supply asks for the roughly 20% derating the factory curve specifies. No step-up transformer needed for US, Canadian or Japanese grids.

How many LED modules can one RSP-150-5 drive?

At the 80% loading rule: 120 W or 24 A usable. A typical indoor P2.5 module draws about 10–15 W of average program material, so one unit covers roughly 8–12 such modules plus the receiving card — verify against your module’s datasheet and brightness profile.

Does the RSP-150 have a fan?

No — the datasheet specifies cooling by free air convection in the perforated 30 mm chassis. It runs silently and does not ingest dust, with a −30 to +70°C working window; note the 3.3–7.5 V rails begin derating near 40°C ambient while the 12–48 V rails hold full load to 50°C.

What is the remote ON/OFF control for?

The CN1 pin pair (JST XH connector) lets external logic switch the DC output: 0–0.8 VDC powers the unit ON, 4–10 VDC powers it OFF. Wire it to a timer, light sensor or room controller to darken the screen on schedule without switching mains.

What is the difference between the RSP-150 and the LRS-150?

The LRS-150 is the value line: no PFC stage, same fanless 30 mm format, focused on the 12–48 V rails. The RSP-150 adds the active PFC front end, the 3.3–15 V low-voltage rails, remote ON/OFF control, 4 kVAC isolation and a 3-year warranty. Choose LRS for cost, RSP for grids, harmonics and control.

Why did my RSP-150 shut off and not come back?

Check which protection tripped. Overload (105–135%) recovers by itself through constant current limiting, and over-temperature recovers once the case cools. Over-voltage is the exception: it latches the output off until you re-power the unit — cycle the AC feed, then find the upstream cause before restarting the screen.

What warranty and service life does Mean Well publish?

A 3-year warranty — a year more than the LRS and NEL lines carry — with a dual-method MTBF: 2,253,900 hours minimum by Telcordia SR-332 plus 290,700 hours minimum by MIL-HDBK-217F at 25°C.

Can I parallel two RSP-150 units for more current?

No. The datasheet lists no current-sharing feature, so paralleled units will not divide load evenly — one runs hot while the other idles. Split the bus by cabinet or step up to a higher-current single supply.

Quote the Mean Well RSP-150 With the Load Math Done

Send your module types and cabinet count; we return per-cabinet power sizing and a matched quote from a LED screen manufacturer that ships worldwide.

📱 / WhatsApp: +86-191-18802497 · Shenzhen, China · GMT+8

More Mean Well Switching Power Supply and LED Display Power Resources

LED Display Power Supply (Mother Catalog)

The three-brand mother catalog: 27 model pages, 2026 price bands, architecture map and the 80% load math — start here.

Open the mother catalog →

Mean Well RSP-1000 (1000 W)

The kilowatt platform: 12–48 V five rails to 1008 W with active current sharing (3+1) and a 5-year warranty.

View the RSP-1000 →

Mean Well RSP-500 (450 W)

The step up: 5 V / 90 A / 450 W with CN100 remote sense, remote ON/OFF and 3-year warranty.

View the RSP-500 →

Mean Well NEL-400 (400 W)

The screen-native sibling: 5 V / 80 A with conformal coating standard, fan-cooled 30 mm chassis.

View the NEL-400 →

Mean Well LRS-600 (500 W)

The big-bay step: 5 V / 100 A / 500 W across seven rails including 27 V.

View the LRS-600 →

LED Display Power Consumption

Screen-level power math: module draw, brightness settings, breaker sizing and cable gauges.

Read the power guide →

Power Supply Diagnostics & Replacement

Test a suspect supply, swap it inside a live screen, and root-cause repeat failures.

Read the diagnostics guide →



Contact Us!

Order LED Screen? Please feel free to contact us at any time, and we will respond to you within 24 hours.